80~260VAC 100A Voltage Current Power Energy Meter + Current Transformer with LCD (PZEM-061)

HS0206
AA0537

Electrical parameter measurement function (voltage, current, active power, energy)

Overload alarm function (over power alarm threshold, backlight and power flashing to alarm).

2133
Χωρίς ΦΠΑ: 17.20
Σε Απόθεμα
+
Στα Αγαπημένα Σύγκριση
Παράδοση
  • — ELTA Courier
  • — ACS Courier
  • — ΓΕΝΙΚΗ ΤΑΧΥΔΡΟΜΙΚΗ
Τρόποι πληρωμής

User Manual : User Manual of PZEM-061

A. Function

Electrical parameter measurement function (voltage, current, active power, energy)

Overload alarm function (over power alarm threshold, backlight and power flashing to alarm).

Power alarm threshold preset function (can set power alarm threshold).

The reset function of energy key.

Store data when power off.

Large-screen LCD (display voltage, current, active power, energy at the same time)

Backlight function.

B. Appearance and Key function

I. Display Interface

Display interface is a large-screen LCD, it can display voltage, current, power, energy parameters at the same time.

II. Display format

Power: test range: 0~22kW

Within 1kW, the display format is 0.0~999.9W

Within 1kW~10kW, the display format is 1000~9999W

10kW and above, the display format is 0.1~22.0kW.

2. Energy: test range: 0~9999kWh

Within 10KWh, the display format is 0~9999Wh;

10kWh and above, the display format is 10~9999kWh.

3. Voltage: test range: 80~260V

Display format: 80~260V

4. Current: test range: 0~100A

Display format: 0.00~99.99A

III. Key

1. Backlight control

Short press the key to turn on or off the backlight, the backlight has memory function, it can store the on or off state when power off.

2. Reset energy

Step1: Long press the key for 5 seconds until the number in energy display window flash, then release the key.

Step2: Short press the key again, then the energy value is cleared and exit the reset flashing state. If you don’t want to clear, then long press the key for 5 seconds again until the number doesn’t flash, it means the energy value is not cleared and will exit the reset state.

3. Set power alarm threshold

Step1: Long press the key until the LCD screen display “SET CLr”, then release the key to enter the setting state

Step2: Power window display the current power alarm value and the last digit begin to flash, then you can short press to plus 1, when there is no operation over 3 seconds, it will switch the digit position automatically, the setting method is as same as the above.

Step3: After finish the setting, long press the key over 5 seconds will store automatically and exit, the range of active power threshold is 0.0--22.0kw

C. Precautions

This module is suitable for indoor, please do not use outdoor.

Applied load should not exceed the rated power.

Wiring order can’t be wrong.

It can't be used for inverter.

D. Specification parameters

Working voltage: 80 ~ 260VAC

Test voltage: 80 ~ 260VAC

Rated power: 100A/22000W

Operating frequency: 45-65Hz

Measurement accuracy: 1.0 grade